Electricalinstallation
9
elecTrical insTallaTion
All electrical inputs and outputs of the device are not galvanically
isolated from the supply voltage.
9.1
safety instructions
Danger!
risk of electric shock.
▶ Before working on equipment or device, switch off the power
supply and secure to prevent reactivation.
▶ Observe applicable accident prevention and safety regulations
for electrical equipment.
Warning!
risk of injury from improper installation.
▶ Installation may be carried out by authorized technicians only
and with the appropriate tools.
risk of injury from unintentional activation of the system and
an uncontrolled restart.
▶ Secure system from unintentional activation.
▶ Following installation, ensure a controlled restart.
Type 8696
9.2
electrical installation with circular
plug-in connector
→
Connect the positioner according to the table.
5
6
4
7
3
8
2
1
Fig. 9:
Circular plug M12 x 1, 8-pole
input signals of the control center (e.g. PLC)
Wire
pin
configuration
color
3)
1
white
Set-point value
+
(0/4 – 20 mA)
2
brown
Set-point value
GND
5
grey
Binary input +
6
pink
Binary input
GND
Tab. 3:
Pin assignment - input signals of the control center
english
external circuit / signal level
1
+ (0/4 – 24 mA)
GND
2
5
+
0 – 5 V
(log. 0)
10 – 30 V (log. 1)
6
GND
15