Type 2000, 2006, 2012
2030, 2031, 2032, 2033
Min./max.strokelimitation
8.3.3 Setting the maximum stroke
→
Interrupt the pilot air supply to close the valve.
→
Loosen locknut (3.4) for maximum stroke.
→
Screw the adjusting nut (3.3) into the desired position for the
maximum stroke.
→
Check the stroke limitation setting by switching the valve.
→
Secure with locknut (3.4) for maximum stroke.
→
Attach tube (6) and screw on cover (7).
CFB
8.3.4 Setting the minimum stroke
→
Unscrew cover (7).
→
Remove tube (6).
→
Loosen the locknut (3.1) for minimum stroke.
→
Screw the adjusting nut (3.2) for the minimum stroke into the
required position.
→
Check the stroke limitation setting by switching the valve.
→
Secure with locknut (3.1) for maximum stroke.
8.3.5 Setting the maximum stroke
→
Apply pilot air to the actuator to close the valve.
→
Loosen locknut (3.4) for maximum stroke.
→
Screw the adjusting nut (3.3) for the maximum stroke into the
desired position.
→
Check the stroke limitation setting by switching the valve.
→
Secure with locknut (3.4) for maximum lift.
→
Interrupt the pilot air supply to open the valve.
→
Attach tube (6) and screw on cover (7).
English
17