5.

PRE-WIRING

CAUTION! WIRING SHOULD BE CARRIED OUT ACCORDING TO THE RULES OF THE ART.
Filtration unit electrical panel
Fuse 4 A
(Soliflow pump protection)
Differential circuit breaker
25 A - 30 mA
Fuse 10 A
(underwater light circuit)
C
1
able
Power supply 230V +
Earth
Cables 2 and 3 should be routed to the Soliflow connection box (see below).
Although cable 3 is only needed if an underwater light is installed, we recommend that you lay it now to facilitate
retrofitting of an underwater light at a later date.
The cable cross section should be 3 x 2.52 for the motor power supply and 2 x 2.52 for the underwater light.
Connection
A :
Pump supply 230 Volts input.
FILTRATION BWT myPOOL
THE ELECTRICAL PANEL SHOULD BE INSTALLED IN A PROTECTED
LOCATION CLOSE TO SOLIFLOW (HOUSE, GARAGE, POOL HOUSE)
C
able
230V + Earth
to the motor
box
2
230 V to the underwaterlight
Connection to the
1
Motor power supply neutral.
2
Earth.
3
Motor power supply live.
2020/02 - Indice de révision : H - Code : 26901
Neutral terminal
Earth terminal
Filtration unit pump timer
C
3
able
transformer
connector
27/40