Show/Hide Bookmarks
Commissioning
Code table
Code
No.
Name
C0190*
Connection of main
v
and additional
d ddi i
l
setpoint
setpoint
(A)
(PCTRL1-ARITH1)
(PCTRL1-ARITH1)
C0191
Acceleration time
compensator
(A)
C0192
Deceleration time
compensator
(A)
C0193
Compensator Reset
(A)
C0194
Min. activation
threshold
(A)
compensator
C0195
Max. compensator
activation threshold
(A)
C0196*
Activation of
v
auto–DCB
DCB
C0200*
Software ID number
C0201*
Software generation
date
Software ID number
C0202*
1
2
3
4
C0220*
Acceleration time
additional setpoint
(PCTRL1-NADD)
C0221*
Deceleration time
additional setpoint
(PCTRL1-NADD)
C0225
Acceleration time
process controller
(A)
setpoint
(PCTRL1-SET1)
C0226
Deceleration time
process controller
(A)
setpoint
(PCTRL1-SET1)
C0228
Unhide time process
controller
(A)
C0229
Hide time process
controller
(A)
C0230
Min. limit process
(A)
controller output
C0231
Max. limit process
controller output
(A)
60
Possible settings
Lenze
Selection
-1-
-0-
X + 0
-1-
X + Y
-2-
X - Y
-3-
X ⋅ Y
C0011
-4-
X
⋅ C0011
Y
100
-5-
X ⋅ C0011
C0011 − Y
5.00
0.00
5.00
0.00
5.00
0.00
-200.00 -200.00
200.00 -200.00
0
0
Auto-DCB active, if PCTRL1-SET3 < C0019
1
Auto-DCB active, if PCTRL1-SET3 < C0019 and
NSET1-RFG1-IN < C0019
82S8212V_xy010
Output to keypad as string in 4 parts à 4 characters
82S8
212V
_xy0
10
5.00
0.00
5.00
0.00
0.00
0.00
0.00
0.00
0.000
0.000
0.000
0.000
-100.0
-200.0
100.0
-200.0
EDK82EV903 DE/EN/FR 1.0
{0.02 s}
1300.00 Ref. to change 0 Hz ... C0011
{0.02 s}
1300.00 Ref. to change C0011 ... 0 Hz
{0.02 s}
1300.00 Ref. to change C0011 ... 0 Hz
{0.01 %}
200.00 Ref. to C0011
{0.01 %}
200.00 Ref. to C0011
{0.02 s}
1300.00 Main setpoint ð C0012
{0.02 s}
1300.00 Main setpoint ð C0013
1300.00 Acceleration encoder for process controller
{0.02 s}
{0.02 s}
1300.00
{0.001 s}
32.000 0.000 = Process controller output is transferred
{0.001 s}
32.000 0.000 = "Fading-off" switched off (C0241)
200.0 Asymmetric limit of process controller output
{0.1 %}
{0.1 %}
200.0
IMPORTANT
Mathematical addition of mains setpoint
p
(NSET1-NOUT) and additional setpoint
(NSET1 NOUT)
d ddi i
l
i
(PCTRL1 NADD)
(PCTRL1-NADD)
The result is in Hz
The result is in Hz
X = NSET1-NOUT
Y = PCTRL1-NADD
Y = PCTRL1-NADD
Decelerate compensator to "0"
If the value falls below C0194:
Compensator "runs" at C0191 or C0192
direction -C0011
If C0195 is exceeded:
Compensator "runs" at C0191 or C0192
direction +C0011
Only PC display
x = main version
y = subversion
Only PC display
Only keypad display
y
yp
p y
x = main version
y = subversion
b
i
setpoint = PCTRL1-RFG2
without unhiding
ref. to C0011
•
If value falls below C0230 or exceeds C0231:
If value falls below C0230 or exceeds C0231:
– Output signal PCTRL1-LIM = HIGH after
time set under C0233
•
Set C0231 > C0230
L