Lenze Global Drive 8200 vector Instructions De Montage page 129

Convertisseur de fréquence
Masquer les pouces Voir aussi pour Global Drive 8200 vector:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Show/Hide Bookmarks
Code
No.
Name
C0036
Voltage/current DC
injection brake (DCB)
C0037
JOG1
C0038
JOG2
C0039
JOG3
C0040*
Controller inhibit
v
C0043*
TRIP reset
v
C0044*
Setpoint 2
(NSET1-N2)
C0046*
Setpoint 1
(NSET1-N1)
C0047*
Torque setpoint or
torque limit value
q
(MCTRL1 MSET)
(MCTRL1-MSET)
C0049*
Additional setpoint
(PCTRL1-NADD)
C0050*
Output frequency
(MCTRL1-NOUT)
u u u u S S S S E E E E r r r r
C0051*
Output frequency
with slip
compensation
(MCTRL1-NOUT
+SLIP) or
Act. process
controller value
(PCTRL1-ACT)
C0052*
Motor voltage
(MCTRL1-VOLT)
C0053*
DC-bus voltage
(MCTRL1-DCVOLT)
C0054*
Apparent motor
current
(MCTRL1-IMOT)
C0056*
Controller load
(MCTRL1-MOUT)
L
Possible settings
Lenze
Selection
à
0.00
20.00
-650.00
30.00
-650.00
40.00
-650.00
-0-
controller inhibited (CINH)
-1-
Controller enabled (CINH)
-0-
No current error
-1-
Active error
-650.00
-650.00
0
Ref.: Rated motor torque detected by motor parameter
identification
-650.00
-650.00
-650.00
0
0
0.0
-255
EDK82EV903 DE/EN/FR 1.0
Commissioning
{0.01 %}
150.00 %
650.00 JOG = Setpoint
{0.02 Hz}
{0.02 Hz}
650.00
{0.02 Hz}
650.00
650.00 The value set will be lost when switching
{0.02 Hz}
{0.02 Hz}
650.00 The value set will be lost when switching
400 The value set will be lost when switching
{%}
{Hz}
650.00 The value set will be lost when switching
{Hz}
650.00 Only display: Output frequency without slip
650.00 The value set will be lost when switching
{Hz}
{V}
1000 Only display
{V}
1000 Only display
{A}
2000.0 Only display
{%}
255 Only display
Code table
IMPORTANT
Depending on the controller
à
Reference M
, I
r
r
Setting applies to all mains voltages
permitted
p
Additional JOG frequencies ð C0440
Controller can only be enabled if X3/28 = HIGH
y
Reset active error with C0043 = 0
the mains!
Selection, if C0412/2 = FIXED-FREE
Display, if C0412/2 ≠ FIXED-FREE
the mains!
Selection, if C0412/1 = FIXED-FREE
Display, if C0412/1 ≠ FIXED-FREE
the mains!
Control mode "Sensorless torque control"
(C0014 = 5):
Torque setpoint selection, if C0412/6 =
FIXED-FREE
Torque setpoint display, if C0412/6 ≠
FIXED-FREE
Control mode "V/f characteristic control" or
"Vector control" (C0014 = 2, 3, 4):
Torque limit value display, if C0412/6 ≠
FIXED-FREE
Function not active (C0047 = 400), if
C0412/6 = FIXED-FREE
the mains!
Selection, if C0412/3 = 0
Display, if C0412/3 ≠ 0
compensation
the mains!
Operation without process controller (C0238 =
2):
Display only: Output frequency with slip
compensation (MCTRL1-NOUT+SLIP)
Operation with process controller (C0238 = 0,
1):
Selection, if C0412/5 = FIXED-FREE
Display, if C0412/5 ≠ FIXED-FREE
51

Publicité

Table des Matières
loading