Finish Framing - After Appliance Installation; Framing With Non-Combustibles - Napoleon Acies Série Manuel D'installation

Masquer les pouces Voir aussi pour Acies Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

10.0 fi nish framing - after appliance installation

10.1 framing with non-combustibles

single-sided fl ush
Ceiling
minimum framing
Ref
K
E
F
J
L
note:
The L series requires a minimum enclosure height of 73" (185.4cm) measured from the bottom of the appliance.
For temperature requirements, this area must be left unobstructed. Some venting confi gurations that require
more vertical rise will require a larger enclosure to provide minimum vertical clearance between vent pipes and
combustibles. It is also recommended that the enclosure be ventilated at the top and bottom to circulate the
hot air.
fi nish framing - after appliance installation
L
J
E
L38
39 15/16" (101.4cm)
17 15/16" (45.6cm)
53 13/16" (136.7cm)
Optional - Appliance does not need to be elevated above fl oor
73" (185.4cm) Min
note:
Shaded components (fi nish framing) must be
non-combustible materials.
Finish framing must be built after the appliance has
been placed in its fi nal position and venting
connected.
K
F
Insulation
L50
39 15/16" (101.4cm)
17 15/16" (45.6cm)
65 13/16" (167.2cm)
73" (185.4cm) Min
Drywall
W415-2033 / B / 02.04.20
EN
43

Publicité

Chapitres

Table des Matières
loading

Table des Matières