MSA PrimaX IR Manuel D'utilisation page 38

Masquer les pouces Voir aussi pour PrimaX IR:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Technical Data
6
Technical Data
MEASURING RANGE
OPERATING
TEMPERATURE
RANGE
STORAGE
TEMPERATURE
RANGE
DRIFT
NOISE
STEP CHANGE
RESPONSE
HUMIDITY
PRESSURE
ACCURACY
SENSOR LIFE
IN-RUSH CURRENT
POWER INPUT
POWER
CONSUMPTION
SIGNAL OUTPUT
PHYSICAL
CHARACTERISTICS
INGRESS
PROTECTION
38
Sensor
Calibration Cap
Sensor
Zero Drift
Span Drift
t50 with
Environmental Guard
t90 with
Environmental Guard
0-50%LEL applied
>50%LEL applied
 chapter 1.3
4-20 mA
LENGTH
WEIGHT
MATERIAL TYPE
PrimaX IR
0-100% LEL
-50 to +75° C [-58 to +167° F]
-30 to +60° C [-22 to +140° F]
-40 to +80° C [-40 to +176° F]
< 1%LEL/ 3 months
<2%LEL/ 3 months
<1% FS
< 7 sec
< 25 sec
Methane and Propane per
FM6310/6320
15 to 95% RH,
non-condensing
600 - 900 mmHg
(80 - 120 kPa)
+/- 3%LEL
+/- 5%LEL
< 350 mA
18 – 32 VDC (Nominal = 24)
including any AC components
< 6.0 W
3-wire current source
203 mm [8.0 in]
1.5 kg [3.3 lb]
316 Stainless Steel
IP67 [3rd party certified]
MSA
US

Publicité

Table des Matières
loading

Table des Matières