Télécharger Imprimer la page

Güde GMP 100 4T Traduction Du Mode D'emploi D'origine page 15

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
Vibration or
1. Too high suction
noisy
lift/total head.
operation
2. Foreign particle
blocks the suction
piping and/or the
pump moving wheel.
3. Unstable installation.
4. Unstable machine
installation.
5. Damaged pump
moving wheel.
6. Other technical
defect.
The engine
1.
Low fuel.
does not start
2.
No ignition spark.
or turns off
3.
Clogged
during
carburettor.
operation.
4.
Clogged air filter.
5.
Activated Auto
Stop because of
low engine oil
level.
6.
Other technical
defect.
Service
Any technical questions? Complaint? Do you need
spare parts or operation manual?
Go to our website www.guede.com and the section
Service will help you quickly and without bureaucracy.
Please, help us to help you. In order to identify your device
in case of complaint, please indicate serial number, order
number and year of manufacture. All information is
available on the product label. To have all information
always at hand, put them down.
Serial number:
Order number:
Year of manufacture:
Phone:
+49 (0) 79 04 / 700-360
Fax:
+49 (0) 79 04 / 700-51999
E-Mail:
support@ts.guede.com
Important information for the customer
Please be sure to know that returning the product in or after
the warranty period must be made in the original packaging.
EU DECLARATION ON CONFORMITY
The company
Güde GmbH & Co. KG
Birkichstrasse 6
74549 Wolpertshausen
Germany,
hereby declares that the design and structure of the devices
listed below and in designs marketed conforms to
applicable basic requirements of the EU directives on safety
and hygiene.
This declaration on conformity becomes void in
case of a change to the device not consulted with
us.
9.
Place the pump
moving wheel
correctly.
10.
Replace the
pump moving
wheel.
11.
Contact the
customer service.
1.
Change the
installation so that
the suction
lift/total head
does not exceed
maximum value.
2.
Remove foreign
particle.
3.
Stabilize the
installation.
4.
Ensure stable
position of the
machine.
5.
Replace the
pump moving
wheel.
6.
Contact the
customer service.
1.
Open the
gasoline cock
and/or refuel.
2.
Check the ignition
switch. Or check
the ignition plugs.
3.
Clean the
carburettor.
4.
Clean air filter.
5.
Replenish engine
oil.
6.
Contact the
customer service.
15
Identification of the devices:
ENGINE PUMP GMP 100 4T
Order No.:
#94253
Applicable EU directives:
2006/42 EG
2004/108 EG
2005/88 EG
2002/95 EG
2004/26 EG
Harmonized standards used
EN 809/AC:2010
EN 1679-1/A1:2011
Type Approval No:
e24*97/68SA*2002/88*0152*00
Date/signature of manufacturer: 12.12.2011
Information about signer:
Technical documentation:
managing director
Mr Arnold
J. Bürkle FBL; QS

Publicité

loading

Ce manuel est également adapté pour:

94253