– Depending on the version, the MonoControl CS must be
fitted to a stable wall in a vertical position or to the top of
the gas cylinder box in a horizontal position. The trigger-
ing element (Figure 3 – A) must always be in a vertical
position.
– Attention must be paid to the installation position.

Protection against dirt / oil

A Truma gas filter must be installed in front of the gas press-
ure regulation system inlet in order to reliably protect it
against dirt / oil. A set of operating and installation instruc-
tions is supplied with the gas filter.

Installation dimensions

~ 80
A
Figure 3
Dimensions in mm. Not shown to scale
18
A
~ 198

MonoControl CS installation and connection

The MonoControl CS must be installed in such a way that the
high-pressure hose connection is in the highest possible lo-
cation, which must be at least higher than the cylinder valve
level (broken line).
The high-pressure hose must slope downwards all the way to
the cylinder valve.
Figure 4
Installation above the cylinder valve makes it more diffi-
cult for gas in the liquid phase to penetrate the low press-
ure section, particularly while driving.
The MonoControl CS is connected to the high-pressure line
via the M20 x 1.5 (G.13) male thread on the inlet side and is
connected to the gas pipe via an 8 mm or 10 mm olive screw
connection (H.9) on the outlet side.
The enclosed Z 10 / RVS 8 adapter (for retail only) must be
used with 30 mbar systems with 8 mm gas pipes.
The MonoControl CS is intended for installation in the gas cyl-
inder box of the caravan or motor home.