6.5

Connect to electrical power supply

Warning!
Electrocution hazard!
Only professional electricians may connect the machine to the power supply accord-
ing to the electro-technological regulations.
For longer unattended break from work or shutdown of the machine pull mains plug
(mains switch function).
Caution!
Loosely laid cables are a tripping hazard!
Lay the power cable to the machine so that it does not pose a tripping hazard. E.g.
cable bridges or connections along the ceiling can be used.
Attention!
Faulty connection values may cause material damage to machine.
Therefore, observe the machine's connection values (see Chap. 3.6).
The specifications on the type label must agree with the data of the electricity grid.
Connect the electrical equipment only at power supply witch is adequately secured
against overcurrent.
Attention!
No function of the electric brake in case of power failure!
In case of power failure, the electronic brake has no function. Here, the machine
must not be run out unattended. do not reach into the danger zone.
Attention!
Avoid short switching cycles!
Because of the enormous thermal stress during the frequent starting and braking the
motor, the electrical box an the elekctronic brake can be damaged.
Attention!
Machine can not be connected to!
• electricity producers, emergency generator, generators
• voltage transformer
• static frequency converters
• mains voltage with a different sinusoidal form.
The machine is intended for operation on an power supply with a system impedance smaller
than 0,39 ohms at the house connection point. The user must ensure that the machine is oper-
ated on an network which satisfies the above requirements. If necessara, the system impedance
can be requested from the local energy supply company.
 Ensure that the cables that connect the BS 450 are equipped with an appropriately dimen-
sioned circuit breaker.
 Ensure that the phase sequence of the outer cable turns clockwise in the receptacle.
 Connect the BS 450 to the power supply by connecting the machine's plug to a receptacle.
We assume no liability for damages resulting from failure to comply with the above points.