Ultra-Lok SRL-Rs do not incorporate an Overload Clutch to limit the force exerted on the drive components and
attached person. Avoid line slack while in Retrieval mode. Also, monitor the individual during retrieval to ensure they
are not subjected to excessive force from continued lifting after entanglement on an obstruction.
;
A minimum load of 75 lbs (33.9 kg) is required to lower or pay out the Lifeline. A force of 30 lbs (0.13 kN) is
required to operate the Retrieval system when loaded to capacity.
;
Stop cranking when the Lifeline is fully extended or retracted. Continued cranking can damage components.
4.7
RETRIEVAL DISENGAGEMENT: To disengage Retrieval mode:
;
When Retrieval mode is disengaged, any extended Lifeline will retract into the SRL. To avoid possible injury, retract
the Lifeline prior to disengagement or hold onto the Lifeline.
1.
Remove any load from the Lifeline.
2.
Pull and hold the Shift Knob in the unlocked position.
3.
Pull the Crank Arm out to disengage and then release the Shift Knob.
4.
Pull out and rotate the Retrieval Handle 180° toward the SRL Body to stowed position.
5.0 INSPECTION
5.1
INSPECTION FREQUENCY: The Ultra-Lok Self-Retracting Device must be inspected at the intervals defined in "Section
2.2 - Inspection Frequency". Inspection procedures are described in the "Inspection & Maintenance Log" (Table 3).
;
Extreme working conditions (harsh environments, prolonged use, etc.) may require increasing the frequency of
inspections.
5.2
UNSAFE OR DEFECTIVE CONDITIONS: If inspection reveals an unsafe defective condition, remove the
Self-Retracting Device from service immediately, mark as "UNUSABLE", and send to an authorized service center for
repair.
;
Only 3M or parties authorized in writing may make repairs to this equipment.
5.3
PRODUCT LIFE: The functional life of 3M Self-Retracting Devices is determined by work conditions and maintenance. As
long as the product passes inspection criteria, it may remain in service.
6.0 MAINTENANCE, SERVICE, AND STORAGE
6.1
CLEANING: Cleaning procedures for the Self-Retracting Device are as follows:
Periodically clean the exterior of the SRL using water and a mild soap solution. Position the SRD so excess water can
drain out. Clean labels as required.
Clean lifeline with water and mild soap solution. Rinse and thoroughly air dry. Do not force dry with heat. An
excessive buildup of dirt, paint, etc. may prevent the lifeline from fully retracting back into the housing causing a
potential free fall hazard. Replace lifeline if excessive buildup is present.
6.2
SERVICE: Additional maintenance and servicing procedures must be completed by an authorized service center. Do not
attempt to disassemble the SRL or lubricate any parts.
6.3
STORAGE AND TRANSPORT: Store and transport Self-Retracting Device in a cool, dry, clean environment out of direct
sunlight. Avoid areas where chemical vapors may exist. Thoroughly inspect the SRL after any period of extended storage.
7.0 LABELS
Figure 19 illustrates labels on the the Ultra-Lok Self-Retracting Devices and their locations. All labels must be present on the
SRD. Labels must be replaced if they are not fully legible. Information provided on each label is as follows:
1) Inspect Snap Hook and Impact Indicator. 2) Inspect locking action of SRD. 3) Connect SRD Lifeline to Back Dorsal Harness Attachment. 4) Vertical applications
A
only. Never anchor the SRD below the Back Dorsal Harness Attachment. 4A) Leading Edge SRL-LE required for anchorage level with or below the Back Dorsal
Harness Attachment. 4B) Vertical applications only. Never anchor the SRD below the Back Dorsal Harness Attachment. 5) Temperature Range -40°C - 60°C 6)
Maximum Capacity - 141 kg 7) Control recoil of the lifeline into the SRD. Never allow the lifeline to recoil freely.
8) Work directly below the SRD Anchorage to minimize Swing Fall. 9) Do not repair. This product must be serviced by an authorized service center. 10) Store
SRDs in a cool, dry, clean environment; out of direct sunlight. 11) Do not load SRD Casing over an edge. 12) Do not remove labels. 13) Read all instructions. 14)
Notified Body ID. 15) Month of next inspection 16) Year of next inspection 17) Year and Month manufactured 18)Lot Number 19) Model Number 20) Lifeline
Length 21) Serial Number
Turn Crank Arm clockwise to lower Lifeline. Turn Crank Arm counterclockwise to raise Lifeline.
B
1) Pull out on the Retrieval Handle. 2) Fold the Retrieval Handle out from the SRL-R Body. 3) Pull out on Shift Knob and hold. 4) Push in and rotate the Crank Arm
C
clockwise slightly. 5) Release the Shift Knob.
ATEX Certified - See "5903010 ATEX Certified Fall Protection Equipment Supplemental".
D
16