2
PRODUCT DESCRIPTION
The devices of this kit and other optional accessories belong to the Nice Home automation system and are designed to automate a swinging gate for
residential use.
CAUTION! – Any use other than that specified herein or in environmental conditions other than those stated in this manual is to be con-
sidered improper and is forbidden
The kit comprises two electromechanical gearmotors with 24 V direct current; they are equipped with a key-operated mechanical release mechanism
that allows for manually moving the gate in case of a power outage.
A command control unit is included that manages the operation of the entire automation. The connection of the control unit to the photocells occurs
through the ECSbus system (a single cable with 2 wires).
The control unit can be powered by fixed mains power (230 V ) or, alternatively, through the SOLEKIT photovoltaic system of the Nice Home range.
If powered from the mains, it can be fitted with a back-up battery (mod. PR100, optional accessory) which ensures that the automation can execute a
certain number of manoeuvres during the hours following a power outage.
3
INSTALLATION
Certain devices and accessories mentioned in this manual are optional and not included in the kit.
The end stops are not included in the kit and do not belong to the Nice Home range of products.
Consult the Nice Home product catalogue or visit the website www.niceforyou.com
3.1 - VERIFYING THE SUITABILITY OF THE GATE AND ENVIRONMENT
• Ensure that the mechanical structure of the gate is suitable for automation and complies with local standards; consult the technical data appearing on
the gate's label. This product cannot automate a gate that is not already secure and efficient; moreover, it cannot resolve defects caused by improper
installation of the gate or poor maintenance of the latter.
• Manually move the gate leaves in the two directions (open/closed) and make sure that the movement takes place with a constant friction at every
point along its course (there should be no points requiring more nor less effort).
• If a gate leaf includes an access door, make sure that it does not obstruct normal gate movement; mount a suitable interlock system if necessary.
• Manually bring the door of the gate into any position then leave it closed and make sure that it does not move.
• Check that there is sufficient space where the gearmotors are installed to allow for effecting a manual release manoeuvre.
• Check that the installation surfaces of the various devices are solid for guaranteeing a stable anchorage and that they are protected and guarded
against accidental knocks. For the photocells, choose a flat surface capable of guaranteeing proper alignment of the pair (Tx and Rx).
3.2 - VERIFYING THE PRODUCT'S APPLICATION LIMITS
Before proceeding with the installation, carry out the following checks and verify the 'Product technical characteristics' (Paragraph 3.3):
• Ensure that all limitations, conditions and warnings appearing in this manual can be fully observed.
3.3 - PRODUCT TECHNICAL SPECIFICATIONS
Model type
Product type
Technology adopted
Maximum inrush torque
Nominal torque
Speed (no load)
Nominal torque speed
Maximum frequency of cycles
Maximum continuous operating time
Application limits
Ambient operating temperature
Protection rating
Dimensions / weight
Model type
Product type
Technology adopted
Mains power supply
Rated power input
Emergency power supply
Flash output
OGI output
16 – English
A
B
Step
Step
RIVA200M
Electromechanical gearmotor for automation of automatic gates and doors
A 24 V
motor, reducer with helical gears; mechanical release mechanism.
250 Nm
120 Nm
1.25 RPM
1 RPM
60 cycles/hour
10 minutes
The structural features make it suitable for use on gates with a weight of up to 200 kg or a
leaf length of up to 2.3 m and an opening angle of up to 180°
-20°C ... +50°C
IP67
230 x 206 x h 88 mm / 15 kg (gearmotor with foundation case)
CLB201
Command control unit for 1 or 2 24 V
complete with radio receiver for "ECCO5..." transmitters
Electronic board governed by an 8 Bit microcontroller with flash technology
A transformer inside the control unit, but separated from the board, reduces the mains voltage
to the nominal 24V voltage used in all of the automation system
230 V (+10% –15%) 50/60 Hz
170W; at peak the power is 360W for a maximum duration of 2s
Provision for "PR100" buffer battery connection
For LED signal lights (mod. FL200)
Programmable output, see paragraph 9.1.1.2 (gate open light 24 V 4W, courtesy light 24 V
4W, Electric lock 12V max 15VA)
motors for automation of automatic gates or doors,