Orange and green lights are
flashing after 24h or charge.
1
Orange and green lights flash al-
ternatively during the charge.
2
The orange led flashes for more
than 3hours and does not turn to
green.
3
Startpack is plugged in to the
mains but no light is on.
4
NO WARRANTY ON BATTERIES
Batteries are active elements, their life depends on maintenance. After each use of this starter, the internal batteries
must be charged. Stored in places with high temperatures can reduce the battery charge. In case of non-use, it is
strongly recommended to recharge the batteries before use. Generally, we recommend leaving the product permanently
plugged to maintain the batteries at their best level of performance. This product is equipped with 2 high performance
batteries which can be irreversibly damaged in case of non compliance of the maintenance rules.
For this reason the batteries of the Startpack are excluded from warranty
12
STARTPACK 12.24
Batteries damaged, no voltage
despite the charge.
Thermal protection of the charger. Charger is overheating because
The battery is sulphated or deeply
discharged.
No voltage from the mains.
The fuse has blown.
The voltage connector is not plug-
ged on the 12V socket.
Unplug the product from the main
and plug it again to start a new
charge. If the problem appears
again the batteries are damaged.
the temperature is too high. The
charger will restart the charge au-
tomatically as soon as the tempe-
rature dropped down sufficiently.
Normal process of the Startpack:
the charger detects the presence
of sulphated / deeply discharged
batteries. It will attempt to re-
cover the battery with a specific
charge of 16h.
Check the presence of 230V vol-
tage on the supply.
Replace the fuse.
Plug the voltazge connector on