Operation With Acknowledgment Pulse - Siemens 6GK1970–5CA20–0AA2 Instructions De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Infrared Link Modul (ILM)
6.3

Operation With Acknowledgment Pulse

For operation of the PROFIBUS ILM with acknowledgment pulses, a manual setting must made during
configuration. Operation with acknowledgment pulse is only intended for the use of point-to-point links between
two PROFIBUS ILMs.
Note
If a point-to-multipoint topology is being used, this mechanism must be deactivated otherwise problems can
occur on the bus.
1
2
3
4
5
Switch 4:
Link monitoring with acknowledgment pulse
4
Operation without acknowledgment
pulse
4
Operation with acknowledgment pulse
Figure 9:
Operation with Acknowledgment Pulse and the Corresponding Switch Setting
Copyright  by Siemens
6
7
8
Setting 0
Setting 1
24
6ZB530–3AC30–0BA1
As shipped:
All switches 0