The system informs you that the currently running operating system will be replaced with the version on
your USB drive:
press [EXIT] to abort the operation, or press [ENTER] to proceed with the install procedure: a pop-up will
appear on the display that shows the advancement of the operation; when the procedure is complete, the
organ will automatically restart.
IMPORTANT NOTES
-
The USB drive used for the update must be formatted with FAT or FAT32 file system (not NTFS or
other), otherwise the drive will not be recognized by the system.
-
Do not switch off the organ or disconnect the USB flash drive during the update phase.
-
If a problem occurs during the update procedure (the instrument suddenly shuts down or the progress
bar stops for one minute or longer) try one of these procedures:
switch on or reboot the instrument while the USB drive is connected, then press [ENTER] when the
system requests to complete the update.
if there is no such request, start the update again, following the procedure described in this
paragraph.
if the system displays the error message "RELESE CHECKSUM ERROR" after restarting the
system, write an email to the technical assistance service (service@viscount.it) reporting the error
type as it appears on the second line (SYSTEM or MODEL) and the numbers in the "M:", "V:",
"S:" and "Release" fields. You will receive the files and information necessary to restore the
instrument.
-
At power up, if you see the message "PERIPHERALS UPDATE REQUESTED", press [ENTER] to
perform the required operations to complete the update.
-
If the system displays the error message "FILE LOAD FAILED – USB PEN ERROR", delete the
update file from your USB drive, then save it again to the pen drive. Should the problem persist, try
with a different USB drive.
-
The system displays the error message "USB PEN NOT PRESENT" when accessing the function
without a USB drive connected to the instrument, or when the pen drive has not been recognized.
VERIFYING THE OPERATING SYSTEM VERSION (SYS. INFO function)
Use this function to verify the release of the operating system currently running on your instrument, then
look for available updates on the website www.viscountinstruments.com. To do so, select the SYSTEM
field on the display under the SETTINGS menu: