OPERATING THE HOOD 
Power/Power‐Off Delay 
Button functions: 
Power: Power ON/OFF the range hood and activate power‐off delay timer. 
Decrease: To decrease Blower (motor) speed, to decrease timer and to enter timer mode. 
Increase: To increase Blower speed, to increase timer and to reset cumulative timer. 
Blower Speed Indicator: Shows current blower speed (1‐6). 
Light: To turn ON/OFF and to dim halogen lights. 
Power‐Off Delay Digital Timer: Indicates the length of time left for the 'delay off' function. 
Controls: 
 
Automatic cleaning reminder: 
This range hood is equipped with a cleaning reminder that will activate after 30 hours of use. 
When blower (motor) starts to rotate, cumulative running time will be shown in Power‐On 
Elapsed Digital Timer. This "C" icon flashes when 30 hours of usage is up and reminds user to
 clean the aluminum filters. 
After cleaning the filters and when the motor is not in use, press and hold the Increase (+) 
button  over  3  seconds  to reset  the  timer. Please  note that  turning  off  the  system will  not 
reset the Power‐On Elapsed Digital Timer. 
 
Adjusting the blower (motor) speed: 
Press  Power  button  once  to  turn  on  the  system.  The  Blower  Power  Indicator  icon  flashes, 
showing that the blower is ready. Decrease (‐) button will decrease the speed of the blower 
from 6 to 1 (strongest to quietest).  Increase (+) button will increase the speed of the blower 
from 1 to 6 (quietest to strongest). 
Press Power button once to turn off the system
Decrease 
Blower Speed Indicator 
Power‐Off Delay Digital Timer 
Cleaning Reminder Indicator 