UK
Installation
ACONTACT YOUR NEAREST AUTHORISED SERVICE CENTRE TO CONNECT THE BARBECUE TO A METHANE
SUPPLY (G20 AT 20 MBAR).
REFER TO CURRENT REGULATIONS TO FIT OR REPLACE THE RUBBER PIPE. THE PIPE'S EXPIRY DATE IS
PRINTED ON THE PIPE ITSELF. ENSURE THE PIPE IS REPLACED BEFORE THIS DATE.
SHOULD THE GAS BOTTLE NOT BE FITTED WITH A STOP VALVE, A SHUT-OFF TAP SHOULD BE USED. THE
TAP MUST BE EASILY ACCESSIBLE.
DO NOT OBSTRUCT THE VENTS IN THE BOTTLE COMPARTMENT. THE GAS BOTTLE MUST BE REPLACED
AWAY FROM ANY POWER SOURCE.
Table of burners, nozzles and gas consumption characteristics
BURNERS
Rated power
Reduced power
CONSUMPTION
G20 20mbar
G30 28..30mbar
NOZZLE DIAMETER
G30 28..30mbar
G30 50mbar
G20 20mbar
G25 25mbar
G25 20mbar
BY-PASS DIAMETER
G30 28..30mbar
G30 50mbar
G20 20mbar
G25 25mbar
G25 20mbar
52
14
GRILL
kW
6.20
kW
2.20
3
m
/h
0.590
g/h
450.82
G31 37mbar
n°
127
G31 50mbar
n°
110
n°
190
n°
200
n°
220
G31 37mbar
n°
Reg.
G31 50mbar
n°
Reg.
mm
Reg.
mm
Reg.
mm
Reg.
SIDE SHELF
TRIPLE-RING
3.30
1.30
0.314
240.146
93
73
128
135
145
Reg.
Reg.
Reg.
Reg.
Reg.
RAPID
3.0
0.75
0.286
219
85
75
115
121
115
Reg.
Reg.
Reg.
Reg.
Reg.