SPM K-Soft Manuel D'utilisation page 40

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

- Once you have correctly mounted the flange,
screw the security knobs right down (fig. 32).
- Once all the components of the freezing
cylinder have been refitted, place all
components of the top tank in the same position
they occupied before the sanitisation (fig. 33).
- Replace the drip tray (fig. 34).
- Once cleaned, before starting up the machine
perform the sanitizing procedure as described in
the next page.
SANITISATION
If the appliance is not used for some days after
being thoroughly cleaned and sanitised as
described in Chapter 9, at restart the following
sanitising operations should be carried out.
- Take off the lid.
- Fill the top tank with water and sanitizer for
objects for food use (use KAY-5
Sanitizer/Cleaner with a 100ppm dilution (1 Oz
®
packet of KAY-5
+2 ½ gallons of water) (the
sanitizing product shall comply with 40 CFR
§180.940), carefully following the doses
prescribed by the manufacturer of the same.
- Start the appliance in wash mode and leave
for the time specified by the manufacturer.
IMPORTANT
Do not leave the sanitizer in the tank for
periods in excess of those prescribed by
the manufacturer
- Empty the tank by opening and closing the tap
at least 10 times in order to sanitise the mix
flow zone too.
- Rinse thoroughly by repeating the same steps
but using only clean water in place of the
sanitizer.
- After carefully performing these operations the
appliance is ready for use.
Date of issue: October, 2018
®
Revision 1
Fig. 32
Fig. 33
Fig. 34
Page 40/72