The build-up of lime scale deposits in the hydraulic
circuit and boiler inhibits thermal exchange, thus
compromising proper operation of the machine.
!
Heavy incrustations in the boiler may cause long
machine shutdowns and in any case invalidate any
guarantee, because this symptom indicates that
regeneration has been neglected.
In order to keep the softener, and hence the
machine, in perfect operating condition, it is neces-
sary to regenerate it regularly, based on use of the
softener and hardness of the water used. The table
below shows the quantity of softened water based
on the hardness of the water in the various units of
measure:
°f: French degree
°d: German degree = 1.8 °f
mg CaCO
3
For further information on softener installation,
start-up and regeneration, refer to the instruction
manual.
Amount of softened water based on hardness
°f
30
40
°d
16,5
22
mg CaCO
30
40
3
8 liters
1000 lt 900 lt
12 liters
1500 lt 1350 lt 1050 lt 750 lt
16 liters
2100 lt 1800 lt 1400 lt 1000 lt 2.0 kg
Softener model
8 liters
12 liters
16 liters
48
60
80
33
44
salt
60
80
700 lt
500 lt
1.0 kg
1.5 kg
Amount of salt
1.0 kg
1.5 kg
2.0 kg
Regeneration notification
If the function has been enabled during the
programming, the system measures the amount of
water used by the machine and prompts the user
for regeneration (flashing of "WATER SOFTENER
REGENERATION") when the set amount has been
exceeded.
Once the regeneration has been carried out, the
counter must be reset.
i
To reset the litre count, contact specialised per-
sonnel.

14.2 Milk foaming nozzle

The milk foaming nozzle lets you foam and heat
milk.
Insert the nozzle (A) in the milk so that the sprayer
is completely covered;
turn the steam tap (B) counterclockwise;
wait for the milk to heat and foam;
upon reaching the desired temperature and
foaming, turn the steam tap (B) clockwise.
To adjust the foaming of the milk: unscrew the
cap (C) of the regulator and use a screwdriver on the
screw (D). To increase foaming, turn counterclock-
wise; to reduce foaming, turn clockwise.
B
A
C
D