6. Templates for front plate customization

Customization:
Choose your print custom made label:
Use a laser printer for a better printed colour resistance in the sunlight.
Cut out the outlines.
Installation:
Open the Securaccess disconnect the wires connected to the microphone, the front keypad, the door
key, the memory keys (according to your model).
Take off the PCB fixing screws, lift the PCB and take off the 4 nuts securing the label display
protection.
Slip your label behind the label display, and re-assemble the label display protection with the 4 nuts
as well as the PCB with its fixing screws and all the disconnected wires.
Make sure no wire crosses the label and potentially dims the led backlight.

7. Specifications

Dimensions :
Weather protection :
Working temperature range :
Door latch relay contact:
Power feed behind PABX :
Dialing mode:
(with keypad)
58mm
(Dotted text area)
46mm
295 x 125 mm in the surface mount option
complies with IP65 IK09
-20° up to 50° (Celsius)
up to 60 VA and 2A maximum
Ringing voltage: 25 Volts RMS
Off-hook current: 18mA minimum
Tone or Pulse
(Without keypad)
58mm
46mm
(Dotted text area)