Notice SecurAccess PMR

3.14. Call barring

Call barring parameters allow limiting the keypad dialing
Setting to modify
Call barring activation
1
er
not allowed first digit
2
nd
not allowed first digit
1
er
not allowed first two digits
2
nd
not allowed first two digits
rd
3
not allowed first two digits
4
th
not allowed first two digits
Limitation of digits

3.15. Changing the programming access code

Programming access code setting coming out from factory is : 0000
This code can be modified as indicated below:
Setting to modify
Changing the setting code
Your new access code :

3.16. Reset

Caution: this operation switches back the unit to all factory settings; it also erases all numbers stored
in memories. This operation can be done locally or remotely.
Local reset:
1. Open the unit and access to the PCB
2. Connect the unit to a powered telephone line.
3. Depress the RAZ button located on the PCB for at least 4 seconds (see page 5)
4. The unit starts emitting several "beep" tones during the reset
5. When the unit stops emitting "beep" tones, this means the reset is completed, the unit is back
to factory settings, including the programming code access (0000).
Remote reset:
1. Call the SecurAccess and enter the programming mode (see § 4.2.)
2. Select the reset setting choice code (91) and enter the programming access code and
terminate by entering *9.
Code
Setting choice
Factory settings are shown in grey
8 0
0 : Deactivated (no limit)
1 : Activated
(factory setting)
8 1
Digit not allowed.
# if no digit (factory setting)
8 2
Digit not allowed.
# if no digit (factory setting)
8 3
The two digits not allowed.
## if no digit (factory setting)
8 4
The two digits not allowed.
## if no digit (factory setting)
8 5
The two digits not allowed.
## if no digit (factory setting)
8 6
The two digits not allowed.
## if no digit (factory setting)
8 7
Maximum digits allowed from 01 to 29
« ## » no limitation (factory setting)
« 00 » keypad dialing not allowed
Code
Setting choice
Factory settings are shown in grey
9 0
Enter the new 4 digits access code twice
note : 0000 = factory setting
42
Conf.
*9
*9
*9
*9
*9
*9
*9
*9
Conf.
*9