Notice SecurAccess PMR
1
st
access code door latch N°2
2
nd
access code door latch N°2
3
rd
access code door latch N°2
4
th
access code door latch N°2
5
th
access code door latch N°2
6
th
access code door latch N°2
NO: Normally open
NC: Normally close
COM : COMMON
C
Power
supply
3.12. Time out for no answer
Same as for Chain dialing section (§ Erreur : source de la référence non trouvée).
This setting is used in the chain dialing settings choice and for the automatic hanging up.
If chain dialing is activated, the SecurAccess will automatically dial the following number stored into
the depressed off-hook/memory button after the selected elapsed time before next call.
If chain dialing is deactivated, the unit will automatically hang up.
Setting to modify
Elapsed time before next call
3.13. Conversation timer
Talking time can be limited by programming. When this feature is activated and the preset talk time is
elapsed, the SecurAccess will automatically hang up.
Proceed as shown below :
Setting to modify
Talk time duration
factory setting = 2 seconds
7 2
Enter a 4 digits code, (0000 not allowed)
7 3
Enter a 4 digits code, (0000 not allowed)
7 4
Enter a 4 digits code, (0000 not allowed)
7 5
Enter a 4 digits code, (0000 not allowed)
7 6
Enter a 4 digits code, (0000 not allowed)
7 7
Enter a 4 digits code, (0000 not allowed)
NC
or
NO
Door latch
Code
Setting choice
Factory settings are shown in grey
0 8
0 : 10 seconds
1 : 20 seconds
2 : 35 seconds (factory setting)
3 : 1 minute
4 : 5 minutes
Code
Setting choice
Factory settings are shown in grey
0 7
Enter the number of minutes of talk time (from 0 up to 9).
Note : 0 = no limit (factory setting)
Door latch n°1
NO/NC contact R/T
Up to 60 VA and 2A maximum
Door latch n°2
NO/NC contact R/T
Up to 60 VA and 2A maximum
41
*9
*9
*9
*9
*9
*9
NO
C
NC
NO
C
NC
Conf.
*9
Conf.
*9