Maximun operating pressure:
Liquid temperature range:
Storage temperature:
Relative humidity of the air:
5.
MANAGEMENT
5.1
Storage
All the pumps must be stored indoors, in a dry, vibration-free and dust-free environment, possibly with
constant air humidity. They are supplied in their original packaging and must remain there until the time of
installation. If this is not possible, the intake and discharge ports must be accurately closed.
5.2
Transport
Avoid subjecting the products to needless jolts or collisions.
To lift and transport the unit, use lifting equipment and the pallet supplied standard (if applicable).
5.3
Weights
The adhesive label on the package indicates the total weight of the pump.
6.
WARNINGS
6.1
Skilled technical personnel
It is advisable that installation be carried out by skilled personnel in
possession of the technical qualifications required by the specific
legislation in force.
The term skilled personnel means persons whose training, experience and instruction, as well
as their knowledge of the respective standards and requirements for accident prevention and
working conditions, have been approved by the person in charge of plant safety, authorizing
them to perform all the necessary activities, during which they are able to recognize and avoid
all dangers.
6.2
Safety
Use is allowed only if the electric system is in possession of safety precautions in accordance with the
regulations in force in the country where the product is installed.
6.3
Checking motor shaft rotation
Before installing the pump you must check that the rotating parts turn freely. For this purpose remove the fan
cover from its seat in the motor end cover. Insert a screwdriver in the notch on the motor shaft from the
ventilation side. If there is a blockage, turn the screwdriver, tapping it gently with a hammer. Fig.A
6.4
Responsibility
The Manufacturer does not vouch for correct operation of the pumps if they are
tampered with or modified, run outside the recommended work range or in contrast with
the other instructions given in this manual.
The Manufacturer declines all responsibility for possible errors in this instructions
manual, if due to misprints or errors in copying. The company reserves the right to make
any modifications to products that it may consider necessary or useful, without affecting
the essential characteristics.
ENGLISH
JETCOM
88 psi (6 bar)
EURO-EUROINOX-EUROCOM
(600 kPa):
K
DP
116 psi (8 bar)
JET-JETINOX
(800 kPa):
32 - 95 °F
For all homologated pumps
EN 60335-2-41 (for domestic uses)
0 ÷ 35°C:
32 -104 °F
JET-JETINOX-JETCOM
0 ÷ 40°C:
DP
-10 ÷ +50°C:
K
14 - 104 °F (-10°C to 40°C)
MAX. 95%
2