3.3.16
Resetting all remote control functions
Press the button T10 to reset all the remote control settings.
By doing so all of the settings of the timer are cancelled and the remote control restores all of the default settings.
Furthermore, by pressing button T10, all of the symbols indicated in fig. 52 will appear on the display, thus making it possible to
check the integrity of the display itself.
3.3.17
Managing the unit if the remote control is not available
UNICO MASTER
Should the remote control be lost, the batteries flat or if it is faulty, the appliance may be operated only in automatic mode by
pressing the micro switch positioned underneath the hole located on the console by means of a pointy object.
To switch the air-conditioner off, press the microswitch again.
To restore routing operations in the remote control, you need only issue any command once the remote control is available again.
WALL SPLIT
If it is lost or faulty, or the batteries are flat, the appliance can be run in automatic mode only, by pressing the button below the front
grill (fig. 51).
Press the button once to switch on and then press again to switch off.
If it is activated with a temporary pushbutton the device selects the operating mode according to the room temperature detected.
3.4
ENERGY SAVING ADVICE
-
Always keep the filters clean (see chapter on maintenance and cleaning).
-
Keep the doors and windows closed in the air-conditioned rooms.
-
Keep sunlight out of the room by using curtains, lowering the shades or closing the shutters.
-
Do not obstruct the air flow channels (both inlet and outlet) of the unit; apart from preventing the optimal performance of the
system, this would also jeopardise correct operating and could cause irreparable damage to the unit.
3.5
DIAGNOSIS OF THE PROBLEMS
It is important for the User to distinguish between functional problems and anomalies in relation to the behaviour of the appliance
as foreseen for its normal operation. Furthermore, the most common problems may easily be solved through simple operations
on behalf of the User (See paragraph: Anomalies and solutions), while for all of the other anomalies it is necessary to contact the
Olimpia Splendid Service Centre.
WARNING: Please remember that any attempt to repair the appliance by unauthorised personnel will immediately invalidate
any form of guarantee.
3.5.1
Functional aspects not to be interpreted as problems
-
The compressor does not start up again immediately after a stop (it takes about three minutes to start again).
In the operating logic of the appliance a delay between a compressor stop and its successive restart has been included, so
that the compressor itself is protected against activations that are too frequent.
-
During the heating operation of the heat pump appliances, the flow of hot air may occur some minutes after activation of the
compressor.
Should the fan start at the same time as the compressor, for the first few minutes it would emit cold air into the room (and this
could bother the occupants) since the unit has not yet reached steady running conditions.
-
If UNICO has been activated in Heating mode, SPLIT cannot be activated in Cooling mode.
If UNICO has been activated in Cooling mode, SPLIT cannot be activated in Heating mode. In these cases, SPLIT emits a
sound to confirm it has received the command but cannot execute it.
-
If SPLIT has been activated in Heating mode, UNICO cannot be activated in Cooling mode.
If SPLIT has been activated in Cooling mode, UNICO cannot be activated in Heating mode. I n these cases, UNICO emits a
sound to confirm it has received the command but cannot execute it.
3
55
UNICO TWIN