11. Specifi cation and ordering information
Description
KINAX WT720
1. Version
Standard
ATEX EX
II 2G Ex ia IIC T4 Gb
II 2D Ex ia IIIC T80°C Db
ATEX EX
II 2D Ex tb IIIC T80°C Db
IECEx
Ex ia IIC T4 Gb
Ex ia IIIC T80°C Db
IECEx
Ex tb IIIC T80°C Db
2. Angle area mechanically
Single-Turn (360°)
3. Drive shaft
Standard, shaft Ø 10 mm [0.393"]
Flange, shaft Ø 19 mm [0.748"]
4. Output variable
Current, 4...20 mA, two-wire
5. Electrical connections
Gland standard
Gland with increased strain relief
Sensor plug M12
6. Test protocole
Without protocole
Protocole German
Protocole English
7. Interface
Without a programmable interface
8. Direction of rotation
Direction of rotation clockwise
Direction of rotation counter-clockwise
V-characteristic
9. Measuring range
Basic confi guration (linear, 0 ... 360°)
[°angle], 0...end value:
vmax1:
V-characteristic
[± ° angle]
vmax2:
I out [mA]
20,5
20
4
3,8
0
Endwert
10. Climatic rating / Marine version
Normal climatic rating (rel. humidity annual average ≤ 90 %)
Increased climating rating (rel. humidity annual average ≤ 95 %)
Version GL (Germanischer Lloyd)
12. Declaration of conformity
See page 20.
16
Order code 720 - xxxx xxxx xx
Switching
point:
vmin1:
vmin2:
Umschaltpunkt
Drehwinkel [°]
360
vmax1 vmin1
Article No./Feature
720 –
I out [mA]
20,5
20
vmax1 < vmin1
vmax2 > vmin2
vmin1 = –vmin2
vmax2 – vmax1 ≤ 360
4
Drehwinkel [°]
3,8
vmin2
vmax2
0
1
2
3
4
5
1
1
2
1
1
2
3
0
D
E
0
0
1
2
0
9
Z
0
1
G