Specification And Ordering Information; Technical Data - Camille Bauer KINAX WT 717 Mode D'emploi

Masquer les pouces Voir aussi pour KINAX WT 717:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4. Specification and ordering information
Significance of the digits 1. to 9.
Order Code
1.
Version of the transmitter
Standard,
Measuring output non intrinsically safe
EEx ia IIC T6, ATEX
Measuring output intrinsically safe
2.
Mechanical angle range
Angle range, to 50°
Angle range > 50 to 350°
3.
Sense of rotation
Sense of rotation clockwise
Sense of rotation counter-clockwise
"V" characteristic
4.
Measuring range
Basic configuration, programmed
0 to final value acc. to order
"V" characteristic acc. to order
5.
Characteristic of output variable
Characteristic linear
Function X to the power of 1/2
Function X to the power of 3/2
Function X to the power of 5/2
Acc. to customer
6.
Test certificate
Without test certificate
Test certificate in German
Test certificate in English
7.
Marking the system zero position
System zero position not marked
System zero position marked
8.
Climatic rating
Standard climatic rating
Improved climatic rating
Mounting mode
9.
Without foot, without flange
With foot (mounted)
With flange (mounted)
Note:
The remaining order code digits concern special fea-
tures, e.g. the ancillary gear for extending the measuring
ranges.

5. Technical data

Measuring input
Measuring range of
rotation angle:
Programmable between 0 to 10 and
0 to 50 or
0 to 50 and 0 to 350
14
Measuring output
Power supply:
717–
1
2
Max. residual ripple:
Output variable I
1
2
Ext. resistance (load):
0
1
2
Accuracy data
0
Reference value:
9
Basic accuracy:
Z
Mechanical withstand
0
Permissible vibrations: acc. to EN 60 068-2-6
1
Shock:
2
Permissible static
3
load on the shaft:
4
Mounting position:
0
D
Material
E
Housing (main part):
0
Rear (cover):
1
Cable glands:
0
Regulations
1
Test voltage:
0
Housing protection:
1
Environmental conditions
2
Climatic rating:
°
Polarity reversal protection. The voltage must not fall below 12 V.
1
H = 12 to 33 V DC
(possible with standard version,
non-Ex)
H = 12 to 30 V DC
(necessary with Ex version, type of
protection "Intrinsically safe"
EEx ia IIC T6)
< 0.3% p.p.
:
Load-independent DC current
A
4 to 20 mA, proportional to the
input
H [V] – 12V
R
max. [kΩ] =
ext
H
= DC power supply
1
I
= Output signal end value
A
Measuring span
Error limits ≤ 0.5% with linear cha-
racteristics
acc. to EN 60 068-2-27
For specification concerning the
static load on the shaft the manu-
facturer must be contacted
Any
Steel
Finish QPQ
(nitro-carbonated)
Metal (aluminium)
Metal
500 Veff, 50 Hz, 1 min.
all electrical connections against
housing
IP 67 acc. to EN 60 529
Standard version
Temperature – 25 to + 70 °C
Annual mean relative humidity ≤ 75%
or
Version with improved climatic
rating
Temperature – 25 to + 70 °C
Annual mean relative
humidity ≤95%
IA [mA]

Publicité

Table des Matières
loading

Table des Matières