9. Adaptation from 2wire connection to 3 or
4wire connection and vice versa
Transmitters with the ordering code 707 – ...D (see Section
14 "Specification and ordering information") are designed
for either a two-wire connection with an output range of
4...20 mA or a three or four-wire connection with an out-
put range of 0...20 mA.
If, however, a transmitter be changed from one to the other
(see wiring diagrams in Fig. 4 and 7), the beginning and end
of the measuring range must be readjusted.
10. Reversing the rotation for instruments
with measuring ranges 150°
A switch is provided on angular transmitters with a measu-
ring range > 150° for reversing the direction of rotation. It is
marked S1 (Fig. 9 and Fig. 10).
At the version ...
... with plugin connector remove the S1 sealing screw
(2.2) (Fig. 9, left).
... with screw terminals and cable glands, remove the
3 screws (3.2) and the cover (3.1) (Fig.6, left).
Caution! The screw terminals (4.1) are live.
The 230 V power supply is potentially
dangerous!
Then operate the switch by turning it a quarter of a turn with
a watchmakers screwdriver (2.3 mm diam.) and reset the
beginning and end of the measuring range.
Attention! In instruments with measuring
range less than 150° the switch S1 is not
existing.
Forcing a watchmaker's screwdriver into
the opening will damage the PCB.
11. Spare parts
11.1 Parts common to both versions, i.e. with plugin
connector and with screw terminals and cable glands
Description
1
Foot
for fixing the KINAX WT 707 with ...
... 3 hexagon bolts M6 × 30
... 3 spring washers B6
... 3 washers 6.4/12.5 ×1.6
Flange
for fixing the KINAX WT 707 with ...
... 3 Allen socket screws, M6 ×20
... 3 spring washers B6
... 3 washers 6.4/12.5 ×1.6
11.2 Parts only for versions with plugin connectors
Description
1
Connector case (1.2) without plug (1.1)
The numbers in brackets, e.g. (1.1), are item numbers used in the
1
figures and text above.
11.3 Parts only for versions with screw terminals
and cable glands
Description
Cover (3.1)
for rear (3) with ...
... flat cover seal
... 3 lens-headed screws M4 ×12
... 3 screw sealing rings
... 3 O rings CR 3.0 ×1 for screws
12. Electric commissioning
• Provide a separate power supply for the device in case of
consumer loads with high interference levels.
• Install the entire plant in an EMC-compatible manner.
Installation environment and wiring can affect the EMC of
the device.
• For Versions with explosion protection:
13. Maintenance
The device is free of maintenance. Repairs may only be
carried out by authorized authorities.
14. Specification and ordering information
Significance of digits 1. to 15.
Despription
1.
Version of the transmitter
Standard, measuring output non intrinsically
safe
Ex ia IIC T6 Gb, CENELEC/ATEX,
measuring output intrinsically safe
Order No
Sea water version
997 182
Sea water version with gear
Ex ia IIC T6 Gb, CENELEC/ATEX,
sea water version
Ex ia IIC T6 Gb, CENELEC/ATEX,
sea water version with gear
IECEx Ex ia IIC T6 Gb version
997 190
IECEx Ex ia IIC T6 Gb, sea water version
IECEx Ex ia IIC T6 Gb,
sea water version with gear
2.
Sense of rotation
Calibrated for sense of rotation clockwise
Calibrated for sense of rotation counter-
clockwise
For V-characteristic (not possible for instru-
Order No
ments with additional gear).
988 470
Calibrated for both senses of rotation (for
measuring ranges ≤ 90° only)
1
The regulations according to EN 60079-14,
the equipment safety law, the generally
acknowledged rules of the industry and
these operating instructions are applicable
for installation and operation. In order to
ensure the required IP protection category
according to EN 60529:1991 is achieved, the
cable glands must be properly installed in
the electrical operating equipment.
Order No
997 207
Order-
Code
707
1
2
3
4
7
8
A
B
C
1
2
3
4
27