Les langues disponibles

Alarm
Fault
No water in chamber, or water
H2O
pressure too low
No water at drain, or water pres-
H2O.
sure too low
Oven door opening or closure
OPE
request
Indicates that cleaning is re-
CLE
quired
The cooking chamber probe
E01
has failed or is not properly con-
nected
The product core probe is not
E02
inserted in the food or has failed
The steam discharge probe has
E03
failed
The motor-operated valve is not
E04
positioned correctly
E05
Safety thermostat failure
E06
Overload cutouts tripped
The optional vacuum probe has
E08
failed or is not properly connect-
ed
English
Remedy
Check that mains water is
present or adjust the pressure
(see page 29); if the problem
persists inform the after-sales
service
Check that mains water is
present or adjust the pressure
(see page 29); if the problem
persists inform the after-sales
service
Open or close the oven door
Inform the after-sales service if
this message continues to be
displayed
Clean
Inform the after-sales service
Check the position of the prod-
uct core probe or inform the af-
ter-sales service if it is faulty
Inform the after-sales service
Switch on the oven again and if
the problem persists inform the
after-sales service
Inform the after-sales service
Inform the after-sales service
Press the "Reset" button
- 21 -
Notes
Convection cooking cycles can
still be carried out
Convection and steam cooking
cycles can still be carried out
The cooking cycle does not start
until the door has been opened
or closed as required
The oven's functions are ena-
bled so cooking cycles can be
carried out
The oven's functions are disa-
bled so no cooking cycles can
be carried out
Cooking cycles with product
core probe cannot be carried
out
Convection and steam cooking
cycles can still be carried out
Convection and steam cooking
cycles can still be carried out
The oven's functions are disa-
bled so no cooking cycles can
be carried out
The oven's functions are disa-
bled so no cooking cycles can
be carried out
Disconnect and reconnect the
vacuum probe before starting
the cooking cycle.
If the problem persists, call the
after-sales service