INSTALLATION
Specification
14.3 Heat-up diagram
The heat-up period depends on the degree of scaling and residual
heat. For the heat-up time for a cold water supply at 10 °C and a
maximum temperature setting, see the diagram.
25
20
15
10
5
0
35
40
45
50
55
x Temperature in °C
y Duration in min
Example:
Temperature setting = 65 °C
Heat-up time = approx. 18 minutes
14.4 Country-specific approvals and certifications
See the type plate for test symbols.
14.5 Extreme operating and fault conditions
In the case of faults, a peak temperature up to 105 °C may briefly
occur in the system.
14.6 Energy consumption data
Product datasheet: Conventional water heaters to regulation (EU) no. 812/2013 and 814/2013
Manufacturer
Load profile
Energy efficiency class
Energy conversion efficiency
Annual power consumption
Default temperature setting
Sound power level
Daily power consumption
20
| ESH 10 U-P Plus | ESH 10 O-P Plus
60
65
70
75
80
85
ESH 10 U-P Plus
STIEBEL ELTRON
%
kWh
°C
dB(A)
kWh
ESH 10 O-P Plus
201397
STIEBEL ELTRON
XXS
A
36
507
55
15
2.370
www.stiebel-eltron.com
201398
XXS
A
37
498
55
15
2.320