7 Functional check

7.1 Functional check via the LEDs

The system is functioning properly when the LEDs on the CM Tiny (IQ) flash green (standby) or
light up orange (high voltage active). Any other LED indication signifies a process error or fault.
During normal operation, the "HV OK"-output will become active after the LEDs have turned
orange.
Table 1, LED indications CM (IQ) Tiny
LED indications
Green flashing quickly
Green flashing slowly
Orange
Red
Red flashing slowly, 1Hz
Red flashing quickly, 5Hz
(only CM Tiny IQ)
See chapter 9 (Faults) to resolve problems.

7.2 Functional check via the Manager IQ Easy

The display of the Manager IQ Easy displays information on the status of the CM Tiny IQ. On
the main screen as well as on the device screens, the status of the CM Tiny IQ can be viewed
by means of the background colour. For more information on colours and icons, see chapter
6.3.
Detailed information is provided on the Information/Settings, Graphics, ActionLog and DataLog
tab.
Figure 15, Graphics Tab

7.2.1 Information/settings tab

CMTinyCMTinyIQ_UM_9752097710_NL_D_GB_F_V1_1
Meaning
Start up
Standby, HV output not active
Normal operation, HV output active
1) High voltage overloaded, HV output active
OR
2) Arcing, HV output temporarily not active
1) Generator overheated, high voltage output
temporarily inactive OR
2) Supply voltage too low, HV output unchanged
3) HV OK output overloaded, HS output active
4) Charging pulse too long, HS output unchanged
(only CM Tiny IQ, see also section 6.3.5)
5) Eeprom read error, HS output unchanged
No communication with the Simco-Ion IQ platform,
HV output inactive
Figure 16, ActionLog tab