3 Safety

The following safety guidelines must be observed in order to prevent physical injury and
damage to objects or to the CM Tiny (IQ) itself.
The output current of the CM Tiny (IQ) is limited to max. 0,4 mA.
If the combined capacity of the connected electrodes is lower than 2 nF, then the output of the
generator is safe to touch.
Danger:
-
Make sure that the equipment is properly earthed. Earthing is necessary to ensure safe and
proper operation and to prevent electric shocks upon contact.
-
Touching parts being subjected to a high voltage will result in an electric shock.
-
Exposure to high voltages can be dangerous for people with pacemakers.
-
An electric shock can cause a shock reaction, even from high voltages that are safe to
touch!
Warning:
-
Electrical installation and repairs must be carried out by a skilled electrical engineer with the
relevant training and qualifications.
-
Disconnect the power supply before carrying out work on the unit.
-
The CM Tiny (IQ) must not be used in environments that pose a fire or explosion hazard.
-
De CM Tiny (IQ) is designed solely for charging non-conductive materials in combination
with a charging bar / electrode with a special CM Tiny (IQ)- head that fits on the generator. It
is not advisable to use it for any other purpose.
Note:
-
Making changes, adjustments etc. without prior written consent or carrying out repairs using
non-original parts will invalidate the equipment's guarantee.