9 Faults

Warning:
-
Disconnect the power supply before carrying out work on the unit.
-
Work must only be carried out on the equipment by an electrical engineer with the
relevant training and qualifications.
Table 2, Fault overview chart CM Tiny (connection diagram, analogue 5.3.1)
Problem
All LEDs are off
LEDs do not light
up orange, keep
flashing green
LEDs light up red
LEDs are flashing
red, slow, 1 Hz
CMTinyCMTinyIQ_UM_9752097710_NL_D_GB_F_V1_1
Possible cause
No supply voltage
Wiring fault
Cable break in the M12
connection cable/connector
High voltage set too low
No signal on the
Remote On/Off input
Output voltage set too high,
arcing at the charging
bar/electrode
Short circuit between charging
bar/electrode or HV cable and
earth
Supply voltage too low
"HV OK" output overloaded
Generator overheated
Solution
Switch on 24 V DC supply
voltage
Locate fault and remedy, see 5.3
Replace M12 cable/connector
Increase output voltage by
increasing setpoint (5.3/6.2)
Connect 24 V DC (±3 V) to the
"Remote On/Off" input
Reduce output voltage by
reducing setpoint or increasing
distance to earth
Locate short circuit and eliminate
Restore 21–27 V DC supply
voltage on M12 connector
Eliminate overload (24 V DC >
50 mA)
Make sure the ambient
temperature is lower than 55 ºC