6 Commissioning

Attention:
- The anti-static bar will not work if the emitters are covered.
- Turn on the power.
- When 24 V DC supply voltage is applied and the remote on / off input is activated, the anti-
static bar will switch on.
With a standard Desktop power supply, the remote on / off is already connected to the 24V
supply voltage. When this power supply is used, the rod will switch on immediately.

7 Operational check

The colour of the status LED on the anti-static bar and the LEDs on the optional cable
connector indicate the status of the anti-static bar.
Status
Standby
In operation
Overloaded
- Anti-static bar overheated
- Supply voltage too low
- HV OK signal overloaded
Possible causes of overload:
- contamination of the anti-static bar.
- direct contact between conductive material and the emitters.
- the anti-static bar is placed too close to conductive (machine) parts.
Possible causes of HV OK overload can be:
- short circuit of the HV OK signal.
- load too heavy on the HV OK signal.
- supply voltage too low.
Vicinion_UM_9752152141_NL_D_GB_F_V1_3
LED-Bar
Flashing Green
Green lit
Red lit
Flashing Red
LED-Connector
Green lit
Green, white and orange
lit
Green and white lit
Green and white lit
GB
BE
38