Télécharger Imprimer la page

Connecting The Cm Tiny (Iq); Connection Diagram Cm Tiny (Analogue) - Simco-Ion Charge Master Tiny Notice D'utilisation

Generateur haute tension cc

Publicité

Les langues disponibles

Les langues disponibles

5.3 Connecting the CM Tiny (IQ)

- Connect the earth wire to a guaranteed earthing point on the machine.
- Connect the M12 connector of the connection cable to the generator.
- Safely route the connection cable to the 24 V power supply and the control unit or to the
Simco-Ion IQ platform
- Connect the connection cable as shown in figure 4 (analogue) or figure 5 (with IQ platform).
- Make sure that directly connected charging bars / electrodes (without series resistors) do not
touch or come too close to earthed objects
- Connect the high-voltage cable(s) to the electrode(s), bearing in mind that voltages of up to
20 kV can be generated.
- Turn the locking screw right into the housing of the CM Tiny (IQ).
- Slide the electrode head onto the generator.
- Manually turn the locking screw upwards until it is securely fastened in the
electrode head.
Locking screw
Figure 3, electrode head on the CM Tiny (IQ)

5.3.1 Connection diagram CM Tiny (analogue)

Figure 4, connections of the CM (IQ) Tiny (standard analogue control)
Note:
To ensure correct and safe operation, the blue core (0 V/GND) of the power cable and the
earth wire must both be connected to earth.
CMTinyCMTinyIQ_UM_9752097710_NL_D_GB_F_V1_1
Electrode head
Pin
Name
1
+24 V DC
2
Remote On/Off
3
0 V/GND
4
HV OK
5
SETPOINT (4-20 mA)
CM Tiny (IQ) housing
Standard core colour
Brown
White
Blue
Black
Yellow/Green - Grey
GB