Télécharger Imprimer la page

Connection Diagram Cm Tiny (Iq); Commissioning And Operation; Checking Functionality Of Cm Tiny (Iq); Fine-Tuning The Cm Tiny (Iq) - Simco-Ion Charge Master Tiny Notice D'utilisation

Generateur haute tension cc

Publicité

Les langues disponibles

Les langues disponibles

5.3.2 Connection diagram CM Tiny (IQ)

Figure 5, connections CM Tiny IQ (with Simco-Ion IQ Easy platform)

6 Commissioning and operation

6.1 Checking functionality of CM Tiny (IQ)

-
It is recommended to increase the setpoint for the output voltage from 0.
-
Switch on the supply voltage (24 V DC or Simco-Ion IQ platform).
The LEDs on the generator will quickly flash green during start-up. A CM Tiny IQ will check
whether the Simco-Ion IQ platform or an analogue control is being used during start-up.
-
After start up, the LEDs will flash green slowly as long as no setpoint has been set for the
high voltage. The "HV OK"- output is not active.
-
Connect 24 V DC to the "Remote On/Off" input (standard analogue control) or switch on the
generator through the Simco-Ion IQ platform (chapter 6.3).
-
Increase the setpoint so that the LEDs light up orange. The high voltage and the "HV OK"
output are active. If the CM Tiny is connected as seen in fig. 4 (standard analogue control)
the setpoint can be increased by connecting e.g 7,5 mA (=4 kV) to the setpoint input.
Increasing the setpoint of a CM Tiny (IQ) connected to the Simco-Ion IQ platform is
described in chapter 6.3.

6.2 Fine-tuning the CM Tiny (IQ)

Note:
-
The high voltage value must be set for optimum charging to suit different applications. The
set values must be established by experimenting.
-
If there is no material between the charging bar/charging electrode and earth when the high
voltage is switched on, the CM Tiny (IQ) may, depending on the electrode configuration,
become overloaded, and arcing may occur.
-
Set the setpoint for the output voltage approx. 10% higher than the optimum value, in order
to accommodate process fluctuations. Do not set unnecessarily high values as this may
result in wear and arcing on the charging bar / electrodes.
CMTinyCMTinyIQ_UM_9752097710_NL_D_GB_F_V1_1
Pin
Name
1
+24 V DC
2
Serial (A)
3
0 V/GND
4
Serial (B)
5
0 V/ Earth
CM Tiny IQ
Standard core colour
Brown
White
Blue
Black
Yellow/green - Grey
54

Publicité

loading

Ce manuel est également adapté pour:

Cm tiny