Thunderion; Thunderion Iq; Functional Check; Power Up & Pulse Frequency Indication Thunderion - Simco-Ion ThunderION 2.0 Notice D'utilisation

Masquer les pouces Voir aussi pour ThunderION 2.0:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7 Functional check

The colour of the status LED's on the anti-static bar can be used to determine the status of the
anti-static bar.
Operation
Standby
In operation
Overloaded
Clean bar warning
HV OK output overload
Internal error
No communication
N.A: not applicable
Possible causes of overload are:
- Fouling of the anti-static bar.
- Direct contact between conductive material and the emitters.
- The anti-static bar has been fitted too close to conductive (machine) parts.
Possible causes of HV OK output overload are:
- Short circuit of the HV OK output signal
- Excessive load of the HV OK output signal
7.1 Power up & pulse frequency indication ThunderION
 Green flashing quick for 2 seconds
 Pulse-frequency indication:
Red flashing quick 10x,
green flash (amount of flashes = pulse frequency [Hz])
Red flashing quick 10x,
 Standby (green flashing) or operating mode (green on)
7.2 Power up & communication checkThunderION IQ
 Green flashing quick for 2 seconds
 Communication check
green flash for maximum 5 sec.
 Standby (green flashing), operating mode (green on)
or no communication (red flashing quick)

7.3 External: Bar HV operating OK output ThunderION

The external Bar HV operating OK output is active if the following three conditions are met:
 the supply voltage is present on the M12 connector
 the bar is Remote On/Off input is activated on the M12 connector,
 there is no error.
ThunderION2.0_UM_9752160050_NL_D_GB_F_V1_0
Bar LED

ThunderIon

Green flashing
Green on
Red on
N.A.
Red flashing
Red flashing
N.A
Bar Led

ThunderIon IQ

Green flashing
Green on
Red on
orange
N.A.
Red flashing
Red flashing (quick)
GB