Parameter "Charge Pulse Max Time" (Figure 10) is a setting for a "Warning". When the high
voltage on the CM Tiny IQ output is longer than the set value of "Charge Pulse Max Time", a
Warning appears in the Manager IQ Easy. By default, the "Charge Pulse Max Time" is set to
0.00 Sec (= inactive).

6.3.6 Web voltage

The parameters "Web voltage" and "Web voltage peak" (Figure 9) are values measured on the
Web. For measuring these values, a "Sensor IQ Easy" bar is required. To read out the "Sensor
IQ Easy" values on the CM Tiny IQ, the sensor must be paired to the generator with the
parameter "Paired sensor" (Figure 11).
6.3.7 Arcing
When arcing occurs between the high voltage output of the CM Tiny IQ and earth, the generator
will turn off briefly (0.3 seconds) and a warning will be displayed on the screen of the Manager
IQ Easy. The number of arcings per minute is shown with the parameter "Arcs per minute"
(Figure 15). With the parameter "Max arcs per minute", the maximum number of arcing per
minute can be set (default = 10). When this maximum number of arcing is exceeded, the high
voltage is turned off briefly and an alarm will be displayed on the screen of the Manager IQ
Easy. The high voltage output can be reactivated by setting the CM Tiny to Standby and then
again to Run. When the parameter "Max arcs per minute" is set to 0, the number of sparkovers
per minute is not limited.
Figure 15
GB
CMTinyCMTinyIQ_UM_9752097710_NL_D_GB_F_V1_1
59