Commissioning; Functional Check - Simco-Ion Performax Easy Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6. Commissioning

Note:
- The anti-static bar does not work if the emitters are covered.
- Remove the protective cap from the anti-static bar.
The purpose of the protective cap is to protect the emitters during transport and installation.
- Switch on the power supply.
- Once a 24 V DC power supply is available and the remote on/off input has been activated,
the anti-static bar will switch on.
With a standard Performax Easy desktop power supply, the remote on/off is already connected
to the 24V power supply. If this power supply is used, the bar will therefore switch on
immediately.

7. Functional check

The colour of the status LED on the anti-static bar and of the LEDs on the optional cable
connector can be used to determine the status of the anti-static bar.
Operation
Standby
In operation
Overloaded
HV OK signal overload
Possible causes of overload are:
- Fouling of the anti-static bar.
- Direct contact between conductive material and the emitters.
- The anti-static bar has been fitted too close to conductive (machine) parts.
Possible causes of HV OK overload are:
- Short circuit of the HV OK signal
- Excessive load of the HV OK signal
Performax Easy/Performax Easy Speed_UM_9752152130_NL_D_GB_F_V3_4
Bar LED
Green flashing
Green on
Green, white and orange on
Red on
Red flashing
Connector LED
Green on
Green and white on
Green and white on
42