First Use; Explosion Risk - SATA HRS Mode D'emploi

Masquer les pouces Voir aussi pour HRS:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 169
Description
Max. spraying pressure
Max. temperature of the coating mate-
rial
Air consumption at 3.0 bar
Nozzle diameter
Air connection thread
Weight version HRS without flow con-
trol
Weight version HRS with flow control
Weight version HRS-E with flow control

8. First Use

The pressurized cup spray gun is supplied fully assembled and ready for
operation.
After unpacking, check:
■ Pressurized cup spray gun damaged
■ Scope of supply complete (see chapter 5)
Warning!

Explosion risk

The use of unsuitable compressed air hoses may cause explosions.
→ Only use solvent-resistant, antistatic, undamaged and technically
flawless compressed air hoses with permanent pressure resistance of
minimum 20.0 bar,, inner diameter of minimum 9 mm and bleeder re-
sistance of < 1MOhm, such as SATA air hose (Art. No. 53090).
Notice!
Use a compressed air connection with 1/4" outer thread or suitable
SATA connection nipple.
Use clean compressed air, for example with SATA filter 484 (Art. No.
92320).
Operating Instructions SATA HRS
Variation
with plas-
tic pressure
6.0 bar
50 °C
approx. 100
Nl/min
1.5 mm
1/4'' outer
thread
1010 g
Variation
with alumini-
um pressure
cup
10.0 bar
80 °C
approx. 100
Nl/min
1.5 mm
1/4" outer
thread
920 g
940 g
1300 g
EN