Operating Instructions SATAjet 1000 B (RP/HVLP)
EN
7.
Use
• Use only solvent-resistant, antistatic, undamaged and technically
flawless compressed air hoses with a permanent pressure resistance
of minimum 10 bar, e.g. Art. No. 53090!
The following requirements must be fulfilled:
• Compressed air connection 1/4" male thread or a suitable SATA con-
nection nipple.
• Ensure minimum compressed air volume (air consumption) and pres-
sure (recommended spray gun inlet pressure) according to chapter 2.
• Use clean compressed air, e.g. by installing the SATA filter 484, Art.
No. 92320
• Use an air hose with minimum 9 mm inner diameter (see warnings),
e.g. Art. No. 53090.
Before using the spray gun, heed / check the following points to warrant
safe working:
■ Screws [2-1], [2-2], [2-3], [2-4] and [2-5] fit firmly. Tighten screws if
necessary.
■ Fluid tip [2-2] tightened with a torque of 14 Nm [7-5].
■ Locking screw [10-1] tightened.
■ Technically clean compressed air is being used.
7.1. First Use
■ Blow through the compressed air pipe thoroughly before installation.
■ Purge paint channel with suitable cleaning solution [2-6].
■ Screw connection nipple [2-10] to air connection [1-8].
■ Align the air cap.
Horizontal spray [2-8]
Vertical spray [2-7]
■ Fit paint sieve [2-12] and gravity flow cup [2-13].
118
Warning! Risk of explosion!
Notice!