safe working:
■ Screws [2-1], [2-2], [2-3], [2-4] and [2-5] fit firmly. Tighten screws if
necessary.
■ Fluid tip [2-2] tightened with a torque of 14 Nm [7-5].
■ Locking screw [10-1] tightened.
■ Technically clean compressed air is being used.

9.1. First Use

■ Blow through the compressed air pipe thoroughly before installation.
■ Purge paint channel with suitable cleaning solution [2-6].
■ Screw connection nipple [2-10] to air connection [1-8].
■ Align the air cap.
Horizontal spray [2-8]
Vertical spray [2-7]
■ Fit paint sieve [2-12] and gravity flow cup [2-13].
9.2. Normal Operation
Connect spray gun
■ Connect compressed air hose [2-11].
Fill with material
Notice!
When painting, only use as much material as is required for the specific
procedure.
When painting, maintain the necessary spray distance. After painting,
store or dispose of the material correctly.
■ Unscrew screw-on lid [2-14] from gravity flow cup [2-13].
■ Press drip-stop [2-9] into screw-on lid.
■ Fill gravity flow cup (maximum 20 mm below top edge).
■ Screw the screw-on lid onto the gravity flow cup.
Adjust gun inner pressure
Notice!
The air micrometer [1-5] must be fully opened (vertical position) in the
settings [3-2], [3-3] and [3-4].