Normal Operation; First Use - SATA jet 2000 LAB HVLP Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 185
SATA LAB Automatic Gun Operating Instructions
9.
Operation
Attention!
Loose screws can cause damage to parts or result in malfunctions.
→ Tighten all screws by hand and check that they are screwed tight.

9.1. First use

The automatic gun is supplied fully assembled and ready for operation.
After unpacking, check:
■ Automatic gun damaged.
■ Scope of supply complete (see chapter 5).
Attention!
Using soiled compressed air can cause malfunctions.
→ Use clean compressed air. For example with SATA filter 544.
■ Check that all screws are screwed tight.
■ Screw the fluid tip tight.
■ Rinse material passages with a suitable cleaning solution (see chapter 11).
■ Align air cap and tighten firmly.
■ Connect the control air (min. 3 bar).
■ Connect the spraying air.
■ Connect the material supply.
Note!
Test air caps are available from SATA to help adjust the spraying pa-
rameters (see chapter 13).

9.2. Normal operation

The automatic gun has an internal control. The control air triggers the
control pulse and opens the spraying air valve of the automatic gun, thus
ensuring that pressurised spraying air is always present at the automatic
gun.
EN
129

Publicité

Table des Matières
loading

Table des Matières