To do so, press the UP button briefly twice in succession.
Drive controller
If the single control unit is used as a drive controller, the drive is connected dir-
ectly to the device. External signals are converted into drive commands. The
coding switch 2 must be in the lower position.
Group control unit
If the single control unit is used as a group control unit, other group control
units/drive controllers can be controlled. This control unit can relay external
switching signals.
This function can be used to connect groups and carry out joint switching
commands. The coding switch 2 must be in the upper position.

Setting

Roller shutter/awning or blind
Roller shutter/awning mode (down) or blind mode (up) can be set via the cod-
ing switch 3. In blind mode, the blind moves in touch mode in order to enable
precise positioning of the slats. If a travel button is pressed for more than 1
second, the blind moves in maintained operation.
31 - en