10.1.5.2 Zone Masking Menu
This function allows setting up to eight masks
(variable dimension) with titling option.
1.
Number: Selects the area to be edited.
2.
Enabling: Enables masking of the relative zone.
3.
Start: Sets the initial position of the area.
4.
Stop: Sets the stop position of the mask.
5.
Text: Changes the text displayed when the mask
is enabled.
ZONE MASKING
------------------------
1>NR
:
2 ENAB.:
3 START: +
4 STOP : +
5 TEXT : MASK 1
Fig. 95
44
1
N
0.00
0.00
Example: To enable masking of zone 1 when the
device is in the +15° and +45° position, proceed as
follows:
• Select 1 as value of parameter No.
• Enable zone masking by setting the Enabling value
to Y.
• Set +015.00 as the value of parameter Start.
• Set the Stop parameter value to +045.00.
• If necessary, edit the displayed text by selecting
Text.
Set the Start and Stop menu values to zero
to disable the masking option. If a number
of masks are superimposed, the mask with
the lowest number will prevail over the
others.
Define the masks moving in a clockwise
direction, as shown in the figure.
Stop2=225°
270°
180°
Start2=170°
Fig. 96
Start1=15°
0°
90°
Stop1=45°
MNVCUPTMAXB_1511_EN