If the delivery rate is still too low after cleaning the
nozzle and the ball valve filter, or if the nozzle
and/or the ball valve filter are worn or damaged,
replace the nozzle and/or the ball valve filter by
genuine SOLO replacement parts.

Changing the spray nozzle and the ball valve filter:

See section 9.4
9.4 Changing the spray nozzle and the
ball valve filter
Only the spray nozzles listed in section 13 and the
genuine ball valve filter (part no.: 49 00 539, mesh
aperture: 0.35 mm [0.0138"]) must be used in this
pressure sprayer.
Before disassembling the nozzle attachment,
switch off the pump, unplug the charger from
the charging socket of the device and depressurise
the device! To depressurise the device, with the
pump switched off, hold the spray tube in the
spraying agent tank or in a suitable container for
the spraying agent and operate the shut-off valve
until no more fluid is sprayed.
Changing the spray nozzle or the ball valve filter:
 Rinse the nozzle attachment with clean water.
 Disassemble the nozzle attachment (11).
 Clean the O-rings, the ball valve filter (b) and the
spray nozzle (a) with clean water and a soft
brush. Never use your mouth to blow through
the spray nozzle! Never use hard objects to
clean the nozzles!
 Replace the previous nozzle by the new one or
the previous ball valve filter by the new one.
 Reassemble the components of the nozzle
attachment according to the above figure.
9.5 Information on using the rechargeable
battery
When used properly, the rechargeable battery will
remain in good working order for many years.
It is important to note that the rechargeable battery
should never be fully discharged.
If the operating pressure built by the pump while
spraying drops noticeably and the pump fails to get
the pressure back up to the normal operating level,
stop spraying with the current battery and recharge
the battery.
9 Maintenance, cleaning and storage
If the pressure sprayer with rechargeable battery is
not used for an extended period of time, we
recommend recharging the battery once a month
with the supplied charger. This will prevent the
battery from deep-discharging.
Alternating between two batteries
We recommend purchasing a second rechargeable
battery if you need to be able to keep working
indefinitely without having to stop when the battery
is discharged. The SOLO charging cable (part no.:
59 00 789) is needed to recharge the second
battery independently of the pressure sprayer.
When alternating between two batteries you can
use one of the rechargeable batteries to run the
sprayer while the second rechargeable battery is
recharged by the charger via the separate charging
cable. The batteries are easy to swap – simply
open the protective casing and undo the Velcro
strap (23). Ensure that the polarity is correct when
the cables are connected to the rechargeable
battery (see section 6.1) and that the battery is
firmly secured with the Velcro strap.

9.6 Replacing the fuse

The replacement glass fuse 5x20 mm 4A (part no.:
00 84 055) can be ordered at your local SOLO
dealer.
Replacing the fuse:
 Release the fuse holder (14) with a screwdriver
(turn it half a turn anti-clockwise) and then pull it
out.
 After inserting a new fuse, slide the fuse holder
back in and lock it by twisting it half a turn
clockwise.
If the fuse blows repeatedly, have the device
checked by a specialist SOLO workshop before
returning it into use.

9.7 Greasing the cap gasket

For proper sealing of the spraying agent tank, the
cap gasket must be well greased with silicone
grease.
9.8 Draining the spraying agent tank and
cleaning the spraying agent carrying
parts
Before opening the spraying agent tank and
before disassembling the nozzle attachment,
switch off the pump and depressurise the device!
To depressurise the device, with the pump
switched off, hold the spray tube in the spraying
agent tank or in a suitable container for the spray-
ing agent and operate the shut-off valve until no
more fluid is sprayed.