Inserting the filters

Insert filters into panels and attach to the air distributor.
Figure 28
Figure 29
Figure 30
230 V

electrical connection

The 230 V
electrical connection must always be made
by an expert (in Germany for example in accordance
with VDE 0100, part 721 or IEC 60364-7-721). These instruc-
tions are intended only as additional information for a quali-
fied electrician; electrical work should not be carried out by
unqualified persons.
Connect the mains cable that has been routed to the con-
necting point.
All cables must be secured with clamps!
An insulating device for providing all-pole insulation from
the mains with contact clearance of at least 3.5 mm must be
provided at the vehicle end for carrying out maintenance and
repair work.

Function check / remote control mounting

Attach the mounting for the remote control in the required
location.
All device functions must subsequently be tested as de-
scribed in the operating instructions.
The installer must check that the condensation traps are clear
after installing the system.
The operating instructions must be handed over to the vehicle
owner.
25