10) Airflow/Pressure analogic output signal
Signal between terminals OUT1/OUT2 and GND. 0 - 10 Vdc signal.
With advanced setup it is possible to choose which fan is connected to the output signal. Each output can either be an the
airflow or the pressure of the selected fan. The default selection is airflow of F1 on OUT1 and pressure on F1 on OUT2.
Wiring diagrams : see schematics
DD 9-7TH
1/2
720054
Max. Airflow
2000
Max. Press.
540
DS 11-4
1/2
720062
Max. Airflow
1900
Max. Press.
890
11) Technical Data of the fans
Supply : 230VAC (between 208V and 240V) - Frequency : 50/60Hz
Grounding : ! COMPULSORY !
Electrical protection :
The motor is self-protected against overloading. It is thus NOT necessary to install an electrical overload protection
device. We advise using a short circuit protection device with the following specifications :
- Starting peak of 150 A for 2 to 4 milliseconds. The "softstop" function has to be used to avoid this peak.
- We recommend a class AM protection device.
Recommended protection calibre/motor type
Type
1/3 HP
1/2 HP
3/4 HP
1/1 HP
Indicative non exhaustive list of : a) AM (10x38mm) fuses with manufacturers references, b) references of thermo
magnetic circuit breakers (disjoncteur): select it with D type "slow" reaction curve – cutting power of 10.000A - AC3.
a)
Calibre
Legrand
2A
réf. :130.02
4A
réf. :130.04
8A
réf. :130.08
10A
réf. :130.10
Insulation class
Thermal : B
Mechanical : IP44 - the connectors must be oriented downwards.
Ambiant temperatures : -10°C / +55°C
– UL approved
Conformities :
12) Technical Data of the Kit CPT TAC3
Supply 230VAC (between 208V and 240V) - Frequency : 50/60Hz
Electrical protection: calibre 4A – slow type
CBr4: Mount passcables (PG) M16 or M20 on the plastic box where you have previously punched out the holes to allow
cable passage. Be cautious to punch holes properly to keep tightness.
Outputs Bypass en R1 relays: 230V – maximum 4A.
Outputs to external relays R1/R2/R3/R4/R5: 12Vdc, 50mA/output.
Ambiant conditions: temperature from -20°C to +70°C, humidity from 5 to 85%.
Conformity:
.
.
1 in appendix 1
DD 9-9
DD 10-10
DD 11-11
1/2
3/4
720055
720056
720057
2900
3800
4400
800
1000
DS 12-5
(K)DF 280-114
3/4
1/3
720063
720036/38/77 720037/39/78
2600
1300
1020
360
Calibre
4A
4A
8A
10A
Télémécanique
réf. : DF2-CA02
réf. : DF2-CA04
réf. : DF2-CA08
réf. : DF2-CA10
DP 6-6
DP 9-7TH
1/1
1/2
1/1
720058
720059
2200
3600
985
410
570
(K)DF 280-114
DS 140-60
1/2
75W
720088
1700
400
520
600
b)
Huppertz
Calibre
réf. : D440102
réf. : D440104
réf. : D440108
réf. : D440110
DP 9-7TH
DP 9-9
1/2
1/1
720011
720060
3000
5700
550
860
DS 140-60
DD 160-160
250W
250W
720089
720099
550
800
620
600
Vynckier
2A
réf : 099/37202-000
4A
réf : 099/37204-000
8A
does not exist
10A
réf : 099/37210-000
DS 10-4 TH
DS 10-4
1/3
1/2
720071
720061
1000
1500
490
665
Merlin Gérin
réf : 25111
réf : 25113
does not exist
réf : 25115
25