IF LS Mode
10
V min?
11
V max?
12
m³/h≡Vmin
13
m³/h≡Vmin
14
% on K3?
15
%F34/F12
PRESSURE
16
ALARM?
∆P FAN1
17
∆P FAN3
18
19
INIT Pa REF?
20
m³h INIT
Pa REF INIT
21
xxxx m³h
xxxx Pa
22
END SETUP
IF CPf MODE
10
CPf on F1
11
% on K3?
12
%F34/F12
13
INIT CPf REF?
14
m³h INIT
CPf INIT
15
xxxx m³h
xxxx Pa
16
END SETUP
IF CPs MODE
6
CPs on F1
7
% on K3?
8
%F34/F12
9
INIT CPs REF?
10
m³h INIT
11
CPs INIT
xx,x V
xxxx m³h
xxxx Pa
12
END SETUP
Select minimum voltage value for LS link
Select maximum voltage value for LS link
Select airflow for each F1,F2 fan corresponding to Vmin
Select airflow for each F1,F2 fan corresponding to Vmax
Select multiplier of airflow when contact between terminals +12V and K3 of the CBr is
closed ('night' setup) or when in position III on the CPT.
Select airflow ratio between fans F3,F4 and fans F1,F2
Pressure alarm is optional. Of you do not wish to set a pressure alarm select N(o),
otherwise select Y(es)
If you have selected Y: Configuration of pressure alarm on fan F1:
Select value of pressure increment corresponding to the nominal airflow.
Configuration of pressure alarm on fan F3
Configuration of pressure alarm: Do you wish to (re)define the nominal pressure (different
for F1 and F3 fans) corresponding to a new nominal airflow ?
If you have selected Y: Pressure alarm setup. Enter airflow to define reference pressure.
Initialisation of the reference pressure busy. After 1 minute the CB will memorize the value
of the calculated static pressure on the fan once the INIT airflow is reached.
Display of actual pressure and airflow
The setup is then completed.
Select constant pressure on F1/F2 (F1) or on F3/F4 (F3).
Select multiplier of the CPf instruction when contact between terminals +12V and K3 of the
CBr is closed ('night' setup) or when in position III on the CPT.
Select airflow ratio between fans F3,F4 and fans F1,F2
Setup of CPf fan pressure instruction ?
If you have selected Y: Enter nominal airflow to determine corresponding pressure CPf.
Initialisation of the reference pressure busy. After 1 minute the CB will memorize the value
of the calculated static pressure on the fan once the INIT airflow is reached.
Display of instant value of airflow and pressure of F1 (or F3) while initializing .
Configuration is finished.
Select constant pressure on F1/F2 (F1) or on F3/F4 (F3).
Select multiplier of the CPs instruction when contact between terminals +12V and K3 of the
CBr is closed ('night' setup) or when in position III on the CPT.
Select airflow ratio between fans F3,F4 and fans F1,F2
Setup of CPs fan pressure instruction ?
If you have selected Y: Enter nominal airflow to determine corresponding pressure CPs.
Initialisation of the reference pressure busy. After 1 minute the CB will memorize the value
of the measured static pressure once the INIT airflow is reached.
Display of instant sensor value and value of airflow and pressure of F1 (or F3) while
initializing.