▶ Following installation, ensure a controlled restart.
Risk of short-circuit or escape of media through leaking screw
joints.
▶ Ensure seals are seated correctly.
▶ Carefully screw together coil and device socket or valve and
pipelines.

5.2 Fluid installation

Follow the safety instructions under "5.1".
Installation can be in any position, preferably actuator upright.
Before installation, clean any possible dirt off the pipelines.
For Type 0283 install a dirt filter (≤ 500 µm) upstream of the valve
inlet (Type 0293 already has the dirt filter integrated in the valve).
Seal the pipe connection with PTFE tape.
Attention: The PTFE tape must not get into the device.
Observe direction of flow (see "Fig. 3").
8
english
NOTE!
Caution risk of breakage.
▶ Do not use the coil as a lever arm.
Hold the device with an open-end wrench on the housing and
screw into the pipeline.
Fig. 3:
Identification of flow direction
Identification for flow
direction