7.6.

electrical data

Connections:
DIN EN 175301-803 Form C
for cable plug Type 2506
DIN 43650 Form B
for cable plug Type 2507
Wire connection on request
Power supply:
24 V DC ± 10 % -
max. residual ripple 10%
24 V / 50 Hz
110 / 230 / 50 Hz
± 10%
Voltage tolerance:
Nominal output:
4 W
Nominal operating mode: 100% continuous operation
for block installation
2 W continuous operation on
request
4 W intermittent operation 60%
(30 min)
Note the information specified on the label for
voltage, type of current, and pressure.
english
16
8.2.

fluid installation

Danger!
Risk of injury from high pressure in the equipment!
Before loosening the lines and valves, turn off the pres-
sure and vent the lines.
Installation position:
any, actuator preferably upwards.
Procedure:
Before installation, clean any possible dirt off the pipe-
lines and flange connections.
If required, install a dirt trap to prevent malfunctions.
Pay attention to the flow direction of the valve.
from 1(P) → 2(A) (CF C) or
from 1(P) → 2(B) (CF D)
english
18
Mesh size:
0.2 – 0.4 mm
8.
insTallaTiOn
8.1.
safety instructions
Danger!
Risk of injury from high pressure in the equipment!
Before loosening the lines and valves, turn off the
pressure and vent the lines.
Risk of injury due to electrical shock!
Before reaching into the system, switch off the power
supply and secure to prevent reactivation!
Observe applicable accident prevention and safety
regulations for electrical equipment!
Warning!
Risk of injury from improper installation!
Installation may be carried out by authorized techni-
cians only and with the appropriate tools!
Risk of injury from unintentional activation of the
system and an uncontrolled restart!
Secure system from unintentional activation.
Following installation, ensure a controlled restart.
Body with threaded connection:
Use PTFE tape as sealing material
note!
Caution risk of breakage!
Do not use the coil as a lifting arm.
Hold the device with a suitable tool (Open-end wrench)
on the body and screw into the pipeline.
Valve with flanged connection:
Cover plate
Type 6012
english
17
17
Nut
Coil
Seal
english
19
19